Chint Hydrogen Separation System: Efficient Purification with Cold Start-up Time

Product Details
Customization: Available
Application Fields: Chemical, Electronic, Food, Medical, New Energy, Petroleum, Pharmaceutical, Transportation
Brand Name: Chint
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Full Customization
The supplier provides full customization services
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)
  • Chint Hydrogen Separation System: Efficient Purification with Cold Start-up Time
  • Chint Hydrogen Separation System: Efficient Purification with Cold Start-up Time
  • Chint Hydrogen Separation System: Efficient Purification with Cold Start-up Time
  • Chint Hydrogen Separation System: Efficient Purification with Cold Start-up Time
  • Chint Hydrogen Separation System: Efficient Purification with Cold Start-up Time
  • Chint Hydrogen Separation System: Efficient Purification with Cold Start-up Time
Find Similar Products
  • Overview
  • FAQ
Overview

Basic Info.

Model NO.
CHINT AGII-QP200
Hydrogen Purity
99.999%
Cold Start-up Time
<20 Minutes
Load Range
30%~120%
30%~120%
4.3~4.4kwh/Nm3
Specification
customizable
Trademark
Chint
Origin
Shanghai

Product Description

Product Description

 
Experience unparalleled efficiency with Chint Hydrogen Separation System, boasting low energy consumption, achieving DC energy usage of only 3.9-4.3kW·h/Nm, setting a new standard in energy efficiency.
Our product stands out with an extraordinary high current density, reaching an impressive 8000A/m, ensuring rapid and efficient hydrogen production.
Benefit from seamless operations with our automatic control system, featuring online real-time monitoring and an advanced automatic alarm and shutdown response to handle any abnormalities.
Designed with a high degree of integration, our system is easy to move and offers flexible transportation options, making deployment hassle-free.
Enjoy the benefits of reduced installation workload and a short cycle time, thanks to our innovative design that simplifies the setup process.
Product model Chint-SA20 Chint-SA50 Chint-SA100 Chint-SA200 Chint-SA500
Rated working current (A) 1670 2480 4600 6600 8200
Direct current power consumption (kW) 3.9-4.3 3.9-4.3 3.9-4.3 4.0-4.3 4.0-4.3
Rated hydrogen production capacity (Nm) 20 50 100 200 500
Rated oxygen production volume (Nm²) 10 25 50 100 250
Operating pressure (MPa(G)) 0.8/1.6 1.6 1.6 1.6 1.6
Working temperature (°C) 90±5 90±5 90±5 90±5 90±5
Load regulation(%) 25-110 25-110 25-110 25-110 25-110
Hydrogen purity(%) ≥99.999 ≥99.999 ≥99.999 ≥99.999 ≥99.999
Hydrogen dew point (°C) -65 -65 -65 -65 -65
 
Chint Hydrogen Separation System: Efficient Purification with Cold Start-up TimeChint Hydrogen Separation System: Efficient Purification with Cold Start-up Time
Chint Hydrogen Separation System: Efficient Purification with Cold Start-up TimeChint Hydrogen Separation System: Efficient Purification with Cold Start-up Time
Chint Hydrogen Separation System: Efficient Purification with Cold Start-up Time
Harnessing cutting-edge technologies, we integrate comprehensive solutions with sophisticated designs to provide top-tier alkaline electrolysis water hydrogen production systems for our clients.
Our hydrogen production efficiency far exceeds industry standards, resulting in significant energy consumption reductions, setting us apart as industry leaders.
Embrace the future of energy with a zero carbon emission footprint, ensuring environmentally friendly operations without compromise.
Equipped with a state-of-the-art multi-intelligence monitoring system, our product offers early warnings, rigorous process quality control, and comprehensive performance durability tests.
Our systems promise an extended service life with minimal maintenance needs, adaptable to diverse operational modes, guaranteeing long-term stable performance.
By blending high technical sophistication with cost-effectiveness, our technology sets a remarkable benchmark in the industry.
Hydrogen Purity Cold start-up Time Load Range DC Power Consumption
99.999% <20 minutes 30%~120% 4.3~4.4kWh/Nm3
Chint Hydrogen Separation System: Efficient Purification with Cold Start-up TimeChint Hydrogen Separation System: Efficient Purification with Cold Start-up TimeShanghai Chint Hydrogen Energy Technology Co., Ltd. (CHET) emerges as a strategic power in 2022, born from the collaboration of the esteemed Chint Group, a global leader in smart energy system solutions, and Shanghai Refire Energy Group, a pioneer in hydrogen technology. Dedicated to advancing clean energy solutions, CHET is firmly grounded in 'green electricity + green hydrogen,' playing a crucial role in global carbon neutrality ambitions and promoting a sustainable, green future.Chint Hydrogen Separation System: Efficient Purification with Cold Start-up TimeChint Hydrogen Separation System: Efficient Purification with Cold Start-up TimeChint Hydrogen Separation System: Efficient Purification with Cold Start-up TimeChint Hydrogen Separation System: Efficient Purification with Cold Start-up TimeChint Hydrogen Separation System: Efficient Purification with Cold Start-up TimeChint Hydrogen Separation System: Efficient Purification with Cold Start-up TimeChint Hydrogen Separation System: Efficient Purification with Cold Start-up Time
FAQ
Chint Hydrogen Separation System: Efficient Purification with Cold Start-up TimeQ1: What is the cooperation process for placing an order?
A:
1. Confirm the product requirements (specifications, quantity, and customization).
2. We will provide a formal quotation.
3. After confirming the order, sign the contract and arrange the payment.
4. Commence production, conduct quality inspections, and arrange for shipment.
5. Provide after - sales support after delivery.

Q2: What are the pricing bases for hydrogen energy equipment?
A: The pricing is based on equipment specifications, production costs, customizationrequirements, and order volume.
Contact our sales team and provide detailed requirements to get a customized quota-tion.

Q3: Do your hydrogen energy products have relevant certifications?
A:Our hydrogen-energy equipment meets international standards, holding
ISO9001:2015 certification (CNAS/IAF accredited).
Tested by DEKRA, an international authority, with certified reports. Also awarded Chi-na's "Hydrogen Energy Leader Action" certificate.
Custom certifications available for target markets.

Q4: How do you ensure the quality of hydrogen energy equipment?
A:
We implement strict quality control throughout the production process:
- Raw material inspection: Carefully select suppliers and test incoming materials.
- In - process monitoring: Conduct multi - stage inspections during assembly and pro-duction.
- Pre - shipment testing: Conduct full - function tests on the equipment to ensure com-pliance with standards.

Q5: Where is the factory located and what are the transportation advantag-es?
A:The factory is located in Shanghai, adjacent to the Port of Shanghai. The interna-tional logistics is convenient, ensuring efficient product delivery.

Q6: Do you provide technical support for the installation and operation ofhydrogen energy equipment?
A:Certainly. We provide detailed operation manuals.

Q7: What after - sales services do you offer?
A:
- Warranty service: Provide a one - year warranty for equipment quality issues.
- Spare parts supply: Supply original spare parts promptly.
- Response mechanism: Our after - sales team will respond within 24 hours and pro-vide solutions.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier